# P3.6 first physical experiment — dry-air routing and reaction

Status: protocol and nominal geometry only. Physical measurements: **0**.

The first experiment tests one useful part of CryoPulse: a finite powered air
stream redirected through controlled upper outlets can produce a measurable
downward reaction, with an asymmetric outlet producing a yaw moment. It does
not establish a high-speed stopping distance, a self-charging cycle or a tyre
coefficient. Keep the cold branch separate from this dry, room-temperature rig.

## A measurement boundary that can close

Mount the complete air unit on one six-axis balance: both blowers, collector,
short feed duct, manifold, valves and actuators. Air enters from the stationary
room and leaves through the four measured outlets. Keep power/data leads in
loose symmetric service loops and measure their effect. An external pressurised
hose would apply a feed reaction that could be mistaken for useful duct force;
it is excluded from this first complete-unit force measurement.

Two **Sanyo Denki 9BMB24P2F01** blowers are candidates in parallel, not series.
Each is rated at 24 V, 10.8 W and 4500 rpm, with catalogue maxima of 1.04 m³/min
free airflow and 410 Pa static pressure. These two maxima are different operating
points. A parallel pair does not double static pressure. The measured installed
curve must establish the real flow and input power. Catalogue maximum pressure
is not a certified relief-device setting.

The four-outlet manifold uses 30 mm bare bores, 29.1 mm soft-seat free bores,
split 5 mm stubs, 0.8 mm gate plates and actual ROBOTIS XC330 actuator CAD. The
rig is a 0–40 °C, dry-air concept with a 500 Pa working target and a separate
750 Pa pressure-test target requiring a qualified fixture and procedure. The
full car's 150 ms valve target is not qualified by a 250 ms bench-stroke target.

Select a force-balance mounting and complete-unit mass below its combined
six-axis load envelope. The candidate ATI Nano17 SI-25-0.25 has 35 N Fz range and
250 Nmm moment range; neither number establishes achieved accuracy. Centre the
gravity load over the balance, including the collector and two blowers. Measure
all six static loads before energising. Detailed collector, blower brackets,
balance adapters and guarding remain fabrication-detail work.

## Instruments and declared targets

* Full mounted-system expanded force uncertainty target: 0.02 N; yaw: 0.001 Nm.
  These must be demonstrated by calibration, repeatability and cable tests.
* Dry differential pressure: Sensirion SDP810-500Pa candidate; manufacturer
  range ±500 Pa, accuracy 3% of reading plus 0.1 Pa zero-point accuracy. Its bulk
  silicon temperature is not an independent gas-temperature measurement.
* Independent air temperature, ambient pressure, inlet and four outlet flow
  traverses, blower tachometers, four actual gate angles, supply voltage/current
  on every electrical branch, and common timestamps. Log at 200 Hz or faster.
* Determine each outlet momentum-profile factor from a velocity traverse. A
  uniform-jet approximation is a planning screen, not a measured momentum map.
* Flow uncertainty target 2% requires a suitable calibrated reference. Do not
  install a restrictive meter whose pressure drop consumes the blower margin.

## Commission and calibrate

1. Independently inspect the as-built bore, gate travel, seats, stubs, joints,
   balance mount and electrical limits. Complete the separately qualified leak
   and pressure checks. Do not connect liquid nitrogen to this rig.
2. Calibrate force and moment in both directions using traceable loads over the
   actual measurement range. Include cross-axis terms and the installed cables.
3. Record zero before and after each run. Repeat the zero with leads in the
   allowed positions. Retain this variation as uncertainty, not a fitted force.
4. Establish actual blower flow/pressure/power curves with open outlets first.
   Pressure-trip target 375 Pa; verify real overshoot and instrument response.
   The operating limit is the lowest qualified component/fixture limit.
5. Characterise each gate's angle, stroke time, current, temperature, opening
   hysteresis and leakage. Stall torque is not a continuous actuator rating.

## Preregistered sequence

Use at least five independent repeats per steady state, randomise state order,
settle for 5 s, retain 10 s of steady data and a separate transition trace.
Repeat an all-open reference between asymmetric states to track drift.

* Blowers off; valves all open; all channels and zeros recorded.
* Both blowers at 25%, 50%, 75% and 100% PWM with all outlets open.
* At the highest qualified steady point: each single gate closed in turn, each
  bank isolated, and mirror-image left/right restrictions.
* All four gates step open/closed at the verified low-pressure duty, with actual
  angle and full electrical input logged. Do not hold an unqualified stall.
* Repeat relevant states with the alternative valve/stub assembly only after a
  matched flow comparison is defined. Preserve both equal-flow and equal-power
  comparisons; either can answer a different engineering question.

## Reduction and acceptance

Choose +z downwards for reported reaction and document the balance transform.
Integrate measured velocity profiles and outlet pressure forces to predict
reaction for the **complete-unit boundary**. For a simple planning estimate with
equal outlets and ambient exit pressure, Fdown = ρ Q² sin(130°) / A_total. This
formula predicts about 0.20 N at 25 L/s for four 30 mm exits and ρ=1.2 kg/m³. It
does not promise that the chosen blowers reach that flow.

Estimate mean uncertainty from repeat runs and one-second blocks, so correlated
200 Hz samples are not treated as independent. Add calibration, zero drift,
cross-axis, lead/fixture, flow-profile and dimensional uncertainties. Report
coverage assumptions. A retained synthetic software check is labelled SYNTHETIC
and must never be counted as a physical run.

Accept a downward-reaction demonstration only when the lower uncertainty bound
of the zero-corrected force is positive, the measured control-volume balance
closes within its combined uncertainty, and electrical input is fully recorded.
Accept controlled yaw only when mirror restrictions reverse the moment with
consistent sign and uncertainty. Publish leakage, response and losses even if a
target is missed; change the gate, collector or control and repeat matched runs.

## Primary supplier references

* https://products.sanyodenki.com/en/sanace/dc/blower/9BMB24P2F01/
* https://docs.robotis.com/docs/dxl/model_reference/x_series/xc_series/xc330-m288/
* https://sensirion.com/products/catalog/SDP810-500Pa
* https://www.ati-ia.com/products/ft/ft_models.aspx?id=Nano17

No parts have been ordered and no supplier has been contacted.