  "physical_measurements": 0,
  "classification": "STEADY_COMPONENT_OPPORTUNITY_NOT_CLOSED_HARDWARE_OR_VEHICLE",
  "selected_single_stage": {
    "physical_measurements": 0,
    "stages": 1,
    "inlet_temperature_K": 300.0,
    "interstage_expander_outlet_Pa": null,
    "hot_gas_total_pressure_loss_Pa_target": 500.0,
    "steady_nitrogen_kg": 2.0,
    "prepared_nitrogen_inventory_kg": 6.0,
    "remaining_N2_before_unknown_startup_kg": 4.0,
    "hot_gas_kg": 30.0,
    "hot_gas_inlet_K": 700.0,
    "hot_gas_outlet_K": 675.3468185297941,
    "heat_into_nitrogen_J": 859235.0315716269,
    "turbine_shaft_J": 206985.6037098106,
    "generator_DC_J": 186287.04333882954,
    "liquid_pump_DC_J": 3618.018265663327,
    "hot_gas_blower_DC_J": 50755.60339425518,
    "control_DC_J": 2000.0,
    "net_steady_DC_J": 129913.42167891102,
    "gas_exit_temperature_K": 198.79042906769953,
    "boiler_required_UA_W_K": 80.9160112152047,
    "reheater_required_UA_W_K": 0.0,
    "minimum_boiler_pinch_K": 401.38424372893434,
    "minimum_reheat_pinch_K": null,
    "resource_availability_used_J": 1950077.8848456582,
    "retained_exit_N2_availability_J": 40675.700936161535,
    "exergy_destroyed_with_ambient_loss_rejection_J": 1779488.7622305858,
    "net_DC_over_resource_availability_used": 0.0666196066775011,
    "turbine_entropy_generation_J_K": 501.9597485061604,
    "total_entropy_generation_J_K": 6070.2328576857835,
    "exergy_entropy_identity_residual_J": -1.3969838619232178e-09,
    "complete_steady_first_law_residual_J": 1.2223608791828156e-09,
    "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
    "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
  },
  "selected_reheated_two_stage": {
    "physical_measurements": 0,
    "stages": 2,
    "inlet_temperature_K": 300.0,
    "interstage_expander_outlet_Pa": 330000.0,
    "hot_gas_total_pressure_loss_Pa_target": 500.0,
    "steady_nitrogen_kg": 2.0,
    "prepared_nitrogen_inventory_kg": 6.0,
    "remaining_N2_before_unknown_startup_kg": 4.0,
    "hot_gas_kg": 30.0,
    "hot_gas_inlet_K": 700.0,
    "hot_gas_outlet_K": 671.6833816227221,
    "heat_into_nitrogen_J": 980128.4495050017,
    "turbine_shaft_J": 238179.56246859708,
    "generator_DC_J": 214361.60622173737,
    "liquid_pump_DC_J": 3618.018265663327,
    "hot_gas_blower_DC_J": 50755.60339425518,
    "control_DC_J": 2000.0,
    "net_steady_DC_J": 157987.98456181886,
    "gas_exit_temperature_K": 241.80621170314464,
    "boiler_required_UA_W_K": 81.48645491705713,
    "reheater_required_UA_W_K": 14.126784741745263,
    "minimum_boiler_pinch_K": 397.72080682186237,
    "minimum_reheat_pinch_K": 401.3842437289328,
    "resource_availability_used_J": 2018351.854692527,
    "retained_exit_N2_availability_J": 10627.997195683827,
    "exergy_destroyed_with_ambient_loss_rejection_J": 1849735.8729350243,
    "net_DC_over_resource_availability_used": 0.07827573977971572,
    "turbine_entropy_generation_J_K": 444.5726908466222,
    "total_entropy_generation_J_K": 6309.861412024649,
    "exergy_entropy_identity_residual_J": -1.3969838619232178e-09,
    "complete_steady_first_law_residual_J": 1.0186340659856796e-09,
    "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
    "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
  },
  "net_steady_DC_gain_J": 28074.562882907834,
  "gain_fraction": 0.21610209722822815,
  "cases": [
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 680.7034888213291,
      "heat_into_nitrogen_J": 645934.1833774324,
      "turbine_shaft_J": 135356.75554389274,
      "generator_DC_J": 121821.07998950347,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 106037.15674462916,
      "gas_exit_temperature_K": 131.13327616455555,
      "boiler_required_UA_W_K": 56.5066890533333,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 500.2772519539785,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1849736.2425812613,
      "retained_exit_N2_availability_J": 154463.37738157553,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1589235.7084550567,
      "net_DC_over_resource_availability_used": 0.057325555018945255,
      "turbine_entropy_generation_J_K": 496.236469650039,
      "total_entropy_generation_J_K": 5421.237279396416,
      "exergy_entropy_identity_residual_J": -2.561137080192566e-09,
      "complete_steady_first_law_residual_J": 1.949956640601158e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 680.9805388258791,
      "heat_into_nitrogen_J": 645934.1833774324,
      "turbine_shaft_J": 135356.75554389274,
      "generator_DC_J": 121821.07998950347,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 95878.65657779512,
      "gas_exit_temperature_K": 131.13327616455555,
      "boiler_required_UA_W_K": 56.47925319615433,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 500.5543019585285,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1844530.141401478,
      "retained_exit_N2_availability_J": 154463.37738157553,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1594188.1074421075,
      "net_DC_over_resource_availability_used": 0.05197998906374406,
      "turbine_entropy_generation_J_K": 496.236469650039,
      "total_entropy_generation_J_K": 5438.131016346952,
      "exergy_entropy_identity_residual_J": -1.1641532182693481e-09,
      "complete_steady_first_law_residual_J": 1.6007106751203537e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 681.8104805962848,
      "heat_into_nitrogen_J": 645934.1833774324,
      "turbine_shaft_J": 135356.75554389274,
      "generator_DC_J": 121821.07998950347,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 65447.45832958497,
      "gas_exit_temperature_K": 131.13327616455555,
      "boiler_required_UA_W_K": 56.39722485210419,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 501.3842437289343,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1828924.964491197,
      "retained_exit_N2_availability_J": 154463.37738157553,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1609014.1287800365,
      "net_DC_over_resource_availability_used": 0.03578466016936475,
      "turbine_entropy_generation_J_K": 496.236469650039,
      "total_entropy_generation_J_K": 5488.705880197984,
      "exergy_entropy_identity_residual_J": -2.3283064365386963e-09,
      "complete_steady_first_law_residual_J": 2.270098775625229e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 683.1897099838382,
      "heat_into_nitrogen_J": 645934.1833774324,
      "turbine_shaft_J": 135356.75554389274,
      "generator_DC_J": 121821.07998950347,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 14875.714119294324,
      "gas_exit_temperature_K": 131.13327616455555,
      "boiler_required_UA_W_K": 56.26143389360168,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 502.7634731164876,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1802959.9900302636,
      "retained_exit_N2_availability_J": 154463.37738157553,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1633620.8985293936,
      "net_DC_over_resource_availability_used": 0.00825071782044627,
      "turbine_entropy_generation_J_K": 496.236469650039,
      "total_entropy_generation_J_K": 5572.645057238253,
      "exergy_entropy_identity_residual_J": 0.0,
      "complete_steady_first_law_residual_J": 3.92901711165905e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 685.933295303888,
      "heat_into_nitrogen_J": 645934.1833774324,
      "turbine_shaft_J": 135356.75554389274,
      "generator_DC_J": 121821.07998950347,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": -85722.41428253373,
      "gas_exit_temperature_K": 131.13327616455555,
      "boiler_required_UA_W_K": 55.993255526533744,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 505.5070584365375,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1751192.979356531,
      "retained_exit_N2_availability_J": 154463.37738157553,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1682452.0162574893,
      "net_DC_over_resource_availability_used": -0.04895086680511482,
      "turbine_entropy_generation_J_K": 496.236469650039,
      "total_entropy_generation_J_K": 5739.218885408464,
      "exergy_entropy_identity_residual_J": -1.862645149230957e-09,
      "complete_steady_first_law_residual_J": 9.313225746154785e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 678.1648560343153,
      "heat_into_nitrogen_J": 729709.0653488855,
      "turbine_shaft_J": 156743.02457240864,
      "generator_DC_J": 141068.7221151678,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 125284.79887029348,
      "gas_exit_temperature_K": 160.85576253550718,
      "boiler_required_UA_W_K": 56.75933570146972,
      "reheater_required_UA_W_K": 8.076786048367051,
      "minimum_boiler_pinch_K": 497.7386191669648,
      "minimum_reheat_pinch_K": 500.2772519539707,
      "resource_availability_used_J": 1897365.4076933926,
      "retained_exit_N2_availability_J": 91130.90242420294,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1680949.7063988962,
      "net_DC_over_resource_availability_used": 0.06603092812923206,
      "turbine_entropy_generation_J_K": 440.2050542305533,
      "total_entropy_generation_J_K": 5734.094171580749,
      "exergy_entropy_identity_residual_J": -4.656612873077393e-10,
      "complete_steady_first_law_residual_J": 1.775333657860756e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 678.4419060388653,
      "heat_into_nitrogen_J": 729709.0653488855,
      "turbine_shaft_J": 156743.02457240864,
      "generator_DC_J": 141068.7221151678,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 115126.29870345944,
      "gas_exit_temperature_K": 160.85576253550718,
      "boiler_required_UA_W_K": 56.731653452298374,
      "reheater_required_UA_W_K": 8.072471810288459,
      "minimum_boiler_pinch_K": 498.0156691715148,
      "minimum_reheat_pinch_K": 500.5543019585207,
      "resource_availability_used_J": 1892174.0395266535,
      "retained_exit_N2_availability_J": 91130.90242420294,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1685916.8383989912,
      "net_DC_over_resource_availability_used": 0.06084339828077308,
      "turbine_entropy_generation_J_K": 440.2050542305533,
      "total_entropy_generation_J_K": 5751.038166123115,
      "exergy_entropy_identity_residual_J": 2.3283064365386963e-10,
      "complete_steady_first_law_residual_J": 1.3096723705530167e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 679.2718478092711,
      "heat_into_nitrogen_J": 729709.0653488855,
      "turbine_shaft_J": 156743.02457240864,
      "generator_DC_J": 141068.7221151678,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 84695.10045524928,
      "gas_exit_temperature_K": 160.85576253550718,
      "boiler_required_UA_W_K": 56.64888916534873,
      "reheater_required_UA_W_K": 8.059575461727523,
      "minimum_boiler_pinch_K": 498.84561094192054,
      "minimum_reheat_pinch_K": 501.38424372892644,
      "resource_availability_used_J": 1876612.925611917,
      "retained_exit_N2_availability_J": 91130.90242420294,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1700786.9227324647,
      "net_DC_over_resource_availability_used": 0.04513189656712628,
      "turbine_entropy_generation_J_K": 440.2050542305533,
      "total_entropy_generation_J_K": 5801.763338674631,
      "exergy_entropy_identity_residual_J": -3.259629011154175e-09,
      "complete_steady_first_law_residual_J": 1.979060471057892e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 680.6510771968244,
      "heat_into_nitrogen_J": 729709.0653488855,
      "turbine_shaft_J": 156743.02457240864,
      "generator_DC_J": 141068.7221151678,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 34123.356244958646,
      "gas_exit_temperature_K": 160.85576253550718,
      "boiler_required_UA_W_K": 56.51188230529559,
      "reheater_required_UA_W_K": 8.038234744646045,
      "minimum_boiler_pinch_K": 500.22484032947386,
      "minimum_reheat_pinch_K": 502.76347311647976,
      "resource_availability_used_J": 1850720.9395192666,
      "retained_exit_N2_availability_J": 91130.90242420294,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1725466.680850105,
      "net_DC_over_resource_availability_used": 0.018437872245516577,
      "turbine_entropy_generation_J_K": 440.2050542305533,
      "total_entropy_generation_J_K": 5885.951495309924,
      "exergy_entropy_identity_residual_J": 6.984919309616089e-10,
      "complete_steady_first_law_residual_J": 1.0913936421275139e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 200.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 683.3946625168743,
      "heat_into_nitrogen_J": 729709.0653488855,
      "turbine_shaft_J": 156743.02457240864,
      "generator_DC_J": 141068.7221151678,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": -66474.77215686941,
      "gas_exit_temperature_K": 160.85576253550718,
      "boiler_required_UA_W_K": 56.24131136196823,
      "reheater_required_UA_W_K": 7.996117829760585,
      "minimum_boiler_pinch_K": 502.96842564952374,
      "minimum_reheat_pinch_K": 505.50705843652963,
      "resource_availability_used_J": 1799098.244197852,
      "retained_exit_N2_availability_J": 91130.90242420294,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1774442.1139305183,
      "net_DC_over_resource_availability_used": -0.03694893948746414,
      "turbine_entropy_generation_J_K": 440.2050542305533,
      "total_entropy_generation_J_K": 6053.017615318162,
      "exergy_entropy_identity_residual_J": -6.984919309616089e-10,
      "complete_steady_first_law_residual_J": 7.639755494892597e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 677.4511014816288,
      "heat_into_nitrogen_J": 753262.9655875411,
      "turbine_shaft_J": 171441.21352036428,
      "generator_DC_J": 154297.09216832786,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 138513.16892345354,
      "gas_exit_temperature_K": 165.086366583511,
      "boiler_required_UA_W_K": 68.16817406806811,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 450.27725195397846,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1910732.3129284373,
      "retained_exit_N2_availability_J": 84056.17587164103,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1688162.968133343,
      "net_DC_over_resource_availability_used": 0.07249218950568995,
      "turbine_entropy_generation_J_K": 500.2270628251881,
      "total_entropy_generation_J_K": 5758.700215361914,
      "exergy_entropy_identity_residual_J": -2.0954757928848267e-09,
      "complete_steady_first_law_residual_J": 2.5029294192790985e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 677.7281514861788,
      "heat_into_nitrogen_J": 753262.9655875411,
      "turbine_shaft_J": 171441.21352036428,
      "generator_DC_J": 154297.09216832786,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 128354.6687566195,
      "gas_exit_temperature_K": 165.086366583511,
      "boiler_required_UA_W_K": 68.13378457281738,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 450.55430195852847,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1905545.1069351928,
      "retained_exit_N2_availability_J": 84056.17587164103,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1693134.2623069324,
      "net_DC_over_resource_availability_used": 0.06735850455046972,
      "turbine_entropy_generation_J_K": 500.2270628251881,
      "total_entropy_generation_J_K": 5775.658408005918,
      "exergy_entropy_identity_residual_J": -2.561137080192566e-09,
      "complete_steady_first_law_residual_J": 2.0372681319713593e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 678.5580932565846,
      "heat_into_nitrogen_J": 753262.9655875411,
      "turbine_shaft_J": 171441.21352036428,
      "generator_DC_J": 154297.09216832786,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 97923.47050840934,
      "gas_exit_temperature_K": 165.086366583511,
      "boiler_required_UA_W_K": 68.03097487946985,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 451.3842437289342,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1889996.441059214,
      "retained_exit_N2_availability_J": 84056.17587164103,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1708016.7946791637,
      "net_DC_over_resource_availability_used": 0.05181145762027463,
      "turbine_entropy_generation_J_K": 500.2270628251881,
      "total_entropy_generation_J_K": 5826.426043592583,
      "exergy_entropy_identity_residual_J": -1.6298145055770874e-09,
      "complete_steady_first_law_residual_J": 2.7066562324762344e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 679.9373226441379,
      "heat_into_nitrogen_J": 753262.9655875411,
      "turbine_shaft_J": 171441.21352036428,
      "generator_DC_J": 154297.09216832786,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 47351.72629811871,
      "gas_exit_temperature_K": 165.086366583511,
      "boiler_required_UA_W_K": 67.86081110890666,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 452.76347311648755,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1864125.0744223278,
      "retained_exit_N2_availability_J": 84056.17587164103,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1732717.1722525682,
      "net_DC_over_resource_availability_used": 0.025401582194152127,
      "turbine_entropy_generation_J_K": 500.2270628251881,
      "total_entropy_generation_J_K": 5910.684537788053,
      "exergy_entropy_identity_residual_J": 6.984919309616089e-10,
      "complete_steady_first_law_residual_J": 8.149072527885437e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 682.6809079641878,
      "heat_into_nitrogen_J": 753262.9655875411,
      "turbine_shaft_J": 171441.21352036428,
      "generator_DC_J": 154297.09216832786,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": -53246.40210370935,
      "gas_exit_temperature_K": 165.086366583511,
      "boiler_required_UA_W_K": 67.5248545220782,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 455.5070584365374,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1812543.1480786428,
      "retained_exit_N2_availability_J": 84056.17587164103,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1781733.3743107112,
      "net_DC_over_resource_availability_used": -0.029376625963443873,
      "turbine_entropy_generation_J_K": 500.2270628251881,
      "total_entropy_generation_J_K": 6077.889729867685,
      "exergy_entropy_identity_residual_J": -4.656612873077393e-10,
      "complete_steady_first_law_residual_J": 1.3606040738523006e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 674.3596136517427,
      "heat_into_nitrogen_J": 855282.0639737798,
      "turbine_shaft_J": 197677.96825309287,
      "generator_DC_J": 177910.17142778359,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 162126.24818290927,
      "gas_exit_temperature_K": 201.35615746310458,
      "boiler_required_UA_W_K": 68.55429778559605,
      "reheater_required_UA_W_K": 10.791448409289067,
      "minimum_boiler_pinch_K": 447.1857641240925,
      "minimum_reheat_pinch_K": 450.27725195397477,
      "resource_availability_used_J": 1968504.1650172882,
      "retained_exit_N2_availability_J": 38184.530915415584,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1768193.3859189632,
      "net_DC_over_resource_availability_used": 0.08236012453724496,
      "turbine_entropy_generation_J_K": 443.2401819063416,
      "total_entropy_generation_J_K": 6031.701811082938,
      "exergy_entropy_identity_residual_J": 2.3283064365386963e-10,
      "complete_steady_first_law_residual_J": 1.7462298274040222e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 674.6366636562927,
      "heat_into_nitrogen_J": 855282.0639737798,
      "turbine_shaft_J": 197677.96825309287,
      "generator_DC_J": 177910.17142778359,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 151967.74801607523,
      "gas_exit_temperature_K": 201.35615746310458,
      "boiler_required_UA_W_K": 68.51951488508257,
      "reheater_required_UA_W_K": 10.785122153954276,
      "minimum_boiler_pinch_K": 447.4628141286425,
      "minimum_reheat_pinch_K": 450.5543019585248,
      "resource_availability_used_J": 1963335.08836661,
      "retained_exit_N2_availability_J": 38184.530915415584,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1773182.8094351192,
      "net_DC_over_resource_availability_used": 0.07740285849141743,
      "turbine_entropy_generation_J_K": 443.2401819063416,
      "total_entropy_generation_J_K": 6048.721846955889,
      "exergy_entropy_identity_residual_J": 2.3283064365386963e-10,
      "complete_steady_first_law_residual_J": -2.9103830456733704e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 675.4666054266985,
      "heat_into_nitrogen_J": 855282.0639737798,
      "turbine_shaft_J": 197677.96825309287,
      "generator_DC_J": 177910.17142778359,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 121536.54976786507,
      "gas_exit_temperature_K": 201.35615746310458,
      "boiler_required_UA_W_K": 68.41553031077638,
      "reheater_required_UA_W_K": 10.766215324072128,
      "minimum_boiler_pinch_K": 448.29275589904825,
      "minimum_reheat_pinch_K": 451.3842437289305,
      "resource_availability_used_J": 1947840.6426526606,
      "retained_exit_N2_availability_J": 38184.530915415584,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1788119.56196938,
      "net_DC_over_resource_availability_used": 0.062395530263887965,
      "turbine_entropy_generation_J_K": 443.2401819063416,
      "total_entropy_generation_J_K": 6099.674439602185,
      "exergy_entropy_identity_residual_J": -4.656612873077393e-10,
      "complete_steady_first_law_residual_J": 3.7834979593753815e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 676.8458348142518,
      "heat_into_nitrogen_J": 855282.0639737798,
      "turbine_shaft_J": 197677.96825309287,
      "generator_DC_J": 177910.17142778359,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 70964.80555757444,
      "gas_exit_temperature_K": 201.35615746310458,
      "boiler_required_UA_W_K": 68.24342600628273,
      "reheater_required_UA_W_K": 10.734941524069093,
      "minimum_boiler_pinch_K": 449.67198528660157,
      "minimum_reheat_pinch_K": 452.76347311648385,
      "resource_availability_used_J": 1922059.0877540885,
      "retained_exit_N2_availability_J": 38184.530915415584,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1812909.7512810985,
      "net_DC_over_resource_availability_used": 0.0369212403560893,
      "turbine_entropy_generation_J_K": 443.2401819063416,
      "total_entropy_generation_J_K": 6184.23930165819,
      "exergy_entropy_identity_residual_J": 2.3283064365386963e-10,
      "complete_steady_first_law_residual_J": -1.5133991837501526e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 250.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 679.5894201343017,
      "heat_into_nitrogen_J": 855282.0639737798,
      "turbine_shaft_J": 197677.96825309287,
      "generator_DC_J": 177910.17142778359,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": -29633.32284425362,
      "gas_exit_temperature_K": 201.35615746310458,
      "boiler_required_UA_W_K": 67.90365302121334,
      "reheater_required_UA_W_K": 10.673268658395147,
      "minimum_boiler_pinch_K": 452.41557060665144,
      "minimum_reheat_pinch_K": 455.5070584365337,
      "resource_availability_used_J": 1870654.7349885749,
      "retained_exit_N2_availability_J": 38184.530915415584,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1862103.5269174129,
      "net_DC_over_resource_availability_used": -0.015841150314910787,
      "turbine_entropy_generation_J_K": 443.2401819063416,
      "total_entropy_generation_J_K": 6352.050236798266,
      "exergy_entropy_identity_residual_J": 1.1641532182693481e-09,
      "complete_steady_first_law_residual_J": -9.677023626863956e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 674.2398267548383,
      "heat_into_nitrogen_J": 859235.0315716269,
      "turbine_shaft_J": 206985.6037098106,
      "generator_DC_J": 186287.04333882954,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 170503.12009395522,
      "gas_exit_temperature_K": 198.79042906769953,
      "boiler_required_UA_W_K": 81.08752661972326,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 400.2772519539786,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1970738.5905193333,
      "retained_exit_N2_availability_J": 40675.700936161535,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1759559.7694892166,
      "net_DC_over_resource_availability_used": 0.0865173701444715,
      "turbine_entropy_generation_J_K": 501.9597485061604,
      "total_entropy_generation_J_K": 6002.250620805791,
      "exergy_entropy_identity_residual_J": -9.313225746154785e-10,
      "complete_steady_first_law_residual_J": 9.89530235528946e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 674.5168767593883,
      "heat_into_nitrogen_J": 859235.0315716269,
      "turbine_shaft_J": 206985.6037098106,
      "generator_DC_J": 186287.04333882954,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 160344.61992712118,
      "gas_exit_temperature_K": 198.79042906769953,
      "boiler_required_UA_W_K": 81.04453170315372,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 400.5543019585286,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1965570.2196772732,
      "retained_exit_N2_availability_J": 40675.700936161535,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1764549.8988139906,
      "net_DC_over_resource_availability_used": 0.08157664291100633,
      "turbine_entropy_generation_J_K": 501.9597485061604,
      "total_entropy_generation_J_K": 6019.2730643492805,
      "exergy_entropy_identity_residual_J": -6.984919309616089e-10,
      "complete_steady_first_law_residual_J": 5.529727786779404e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 675.3468185297941,
      "heat_into_nitrogen_J": 859235.0315716269,
      "turbine_shaft_J": 206985.6037098106,
      "generator_DC_J": 186287.04333882954,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 129913.42167891102,
      "gas_exit_temperature_K": 198.79042906769953,
      "boiler_required_UA_W_K": 80.9160112152047,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 401.38424372893434,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1950077.8848456582,
      "retained_exit_N2_availability_J": 40675.700936161535,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1779488.7622305858,
      "net_DC_over_resource_availability_used": 0.0666196066775011,
      "turbine_entropy_generation_J_K": 501.9597485061604,
      "total_entropy_generation_J_K": 6070.2328576857835,
      "exergy_entropy_identity_residual_J": -1.3969838619232178e-09,
      "complete_steady_first_law_residual_J": 1.2223608791828156e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 676.7260479173474,
      "heat_into_nitrogen_J": 859235.0315716269,
      "turbine_shaft_J": 206985.6037098106,
      "generator_DC_J": 186287.04333882954,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 79341.67746862039,
      "gas_exit_temperature_K": 198.79042906769953,
      "boiler_required_UA_W_K": 80.7033442471037,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 402.76347311648766,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1924299.8264424587,
      "retained_exit_N2_availability_J": 40675.700936161535,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1804282.4480376767,
      "net_DC_over_resource_availability_used": 0.04123145280083665,
      "turbine_entropy_generation_J_K": 501.9597485061604,
      "total_entropy_generation_J_K": 6154.8096470669525,
      "exergy_entropy_identity_residual_J": -2.3283064365386963e-10,
      "complete_steady_first_law_residual_J": -6.693881005048752e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 679.4696332373973,
      "heat_into_nitrogen_J": 859235.0315716269,
      "turbine_shaft_J": 206985.6037098106,
      "generator_DC_J": 186287.04333882954,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": -21256.45093320767,
      "gas_exit_temperature_K": 198.79042906769953,
      "boiler_required_UA_W_K": 80.28366149726656,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 405.50705843653753,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1872902.3867630437,
      "retained_exit_N2_availability_J": 40675.700936161535,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1853483.13676009,
      "net_DC_over_resource_availability_used": -0.011349470791131518,
      "turbine_entropy_generation_J_K": 501.9597485061604,
      "total_entropy_generation_J_K": 6322.644164284803,
      "exergy_entropy_identity_residual_J": 2.3283064365386963e-10,
      "complete_steady_first_law_residual_J": -1.2369127944111824e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 670.5763898477663,
      "heat_into_nitrogen_J": 980128.4495050017,
      "turbine_shaft_J": 238179.56246859708,
      "generator_DC_J": 214361.60622173737,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 198577.68297686306,
      "gas_exit_temperature_K": 241.80621170314464,
      "boiler_required_UA_W_K": 81.66043902709285,
      "reheater_required_UA_W_K": 14.16347623777723,
      "minimum_boiler_pinch_K": 396.6138150469066,
      "minimum_reheat_pinch_K": 400.27725195397704,
      "resource_availability_used_J": 2038925.9320471045,
      "retained_exit_N2_availability_J": 10627.997195683827,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1829720.2518745575,
      "net_DC_over_resource_availability_used": 0.09739327940053656,
      "turbine_entropy_generation_J_K": 444.5726908466222,
      "total_entropy_generation_J_K": 6241.58366663673,
      "exergy_entropy_identity_residual_J": 0.0,
      "complete_steady_first_law_residual_J": 8.149072527885437e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 670.8534398523163,
      "heat_into_nitrogen_J": 980128.4495050017,
      "turbine_shaft_J": 238179.56246859708,
      "generator_DC_J": 214361.60622173737,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 188419.18281002901,
      "gas_exit_temperature_K": 241.80621170314464,
      "boiler_required_UA_W_K": 81.61682473340318,
      "reheater_required_UA_W_K": 14.15427545807291,
      "minimum_boiler_pinch_K": 396.8908650514566,
      "minimum_reheat_pinch_K": 400.55430195852705,
      "resource_availability_used_J": 2033779.2686720872,
      "retained_exit_N2_availability_J": 10627.997195683827,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1834732.0886663743,
      "net_DC_over_resource_availability_used": 0.092644853702857,
      "turbine_entropy_generation_J_K": 444.5726908466222,
      "total_entropy_generation_J_K": 6258.680159189402,
      "exergy_entropy_identity_residual_J": 1.3969838619232178e-09,
      "complete_steady_first_law_residual_J": 3.4924596548080444e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 671.6833816227221,
      "heat_into_nitrogen_J": 980128.4495050017,
      "turbine_shaft_J": 238179.56246859708,
      "generator_DC_J": 214361.60622173737,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 157987.98456181886,
      "gas_exit_temperature_K": 241.80621170314464,
      "boiler_required_UA_W_K": 81.48645491705713,
      "reheater_required_UA_W_K": 14.126784741745263,
      "minimum_boiler_pinch_K": 397.72080682186237,
      "minimum_reheat_pinch_K": 401.3842437289328,
      "resource_availability_used_J": 2018351.854692527,
      "retained_exit_N2_availability_J": 10627.997195683827,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1849735.8729350243,
      "net_DC_over_resource_availability_used": 0.07827573977971572,
      "turbine_entropy_generation_J_K": 444.5726908466222,
      "total_entropy_generation_J_K": 6309.861412024649,
      "exergy_entropy_identity_residual_J": -1.3969838619232178e-09,
      "complete_steady_first_law_residual_J": 1.0186340659856796e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 673.0626110102754,
      "heat_into_nitrogen_J": 980128.4495050017,
      "turbine_shaft_J": 238179.56246859708,
      "generator_DC_J": 214361.60622173737,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 107416.24035152822,
      "gas_exit_temperature_K": 241.80621170314464,
      "boiler_required_UA_W_K": 81.27073476490655,
      "reheater_required_UA_W_K": 14.081335342764831,
      "minimum_boiler_pinch_K": 399.1000362094157,
      "minimum_reheat_pinch_K": 402.7634731164861,
      "resource_availability_used_J": 1992681.3311177548,
      "retained_exit_N2_availability_J": 10627.997195683827,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1874637.0935705428,
      "net_DC_over_resource_availability_used": 0.05390537798197528,
      "turbine_entropy_generation_J_K": 444.5726908466222,
      "total_entropy_generation_J_K": 6394.805026677611,
      "exergy_entropy_identity_residual_J": 1.3969838619232178e-09,
      "complete_steady_first_law_residual_J": -8.440110832452774e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 300.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 675.8061963303253,
      "heat_into_nitrogen_J": 980128.4495050017,
      "turbine_shaft_J": 238179.56246859708,
      "generator_DC_J": 214361.60622173737,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 6818.111949700164,
      "gas_exit_temperature_K": 241.80621170314464,
      "boiler_required_UA_W_K": 80.84505221204837,
      "reheater_required_UA_W_K": 13.991791732042998,
      "minimum_boiler_pinch_K": 401.84362152946557,
      "minimum_reheat_pinch_K": 405.507058436536,
      "resource_availability_used_J": 1941496.4999928772,
      "retained_exit_N2_availability_J": 10627.997195683827,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1924050.3908474932,
      "net_DC_over_resource_availability_used": 0.00351178173626642,
      "turbine_entropy_generation_J_K": 444.5726908466222,
      "total_entropy_generation_J_K": 6563.36479907042,
      "exergy_entropy_identity_residual_J": -4.656612873077393e-10,
      "complete_steady_first_law_residual_J": -1.8917489796876907e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 672.9611664619965,
      "heat_into_nitrogen_J": 901430.8212354075,
      "turbine_shaft_J": 221123.09141541555,
      "generator_DC_J": 199010.782273874,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 183226.8590289997,
      "gas_exit_temperature_K": 212.2383445814292,
      "boiler_required_UA_W_K": 86.70222772354836,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 380.2772519539786,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1994570.8256480815,
      "retained_exit_N2_availability_J": 28696.627099084668,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1782647.3395199971,
      "net_DC_over_resource_availability_used": 0.09186279909085962,
      "turbine_entropy_generation_J_K": 502.36620419582323,
      "total_entropy_generation_J_K": 6081.007468940814,
      "exergy_entropy_identity_residual_J": -2.3283064365386963e-09,
      "complete_steady_first_law_residual_J": 2.9685907065868378e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 673.2382164665465,
      "heat_into_nitrogen_J": 901430.8212354075,
      "turbine_shaft_J": 221123.09141541555,
      "generator_DC_J": 199010.782273874,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 173068.35886216565,
      "gas_exit_temperature_K": 212.2383445814292,
      "boiler_required_UA_W_K": 86.65516868039201,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 380.5543019585286,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1989410.004584087,
      "retained_exit_N2_availability_J": 28696.627099084668,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1787645.0186228368,
      "net_DC_over_resource_availability_used": 0.08699481678657181,
      "turbine_entropy_generation_J_K": 502.36620419582323,
      "total_entropy_generation_J_K": 6098.055666460307,
      "exergy_entropy_identity_residual_J": -2.0954757928848267e-09,
      "complete_steady_first_law_residual_J": 2.5029294192790985e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 674.0681582369523,
      "heat_into_nitrogen_J": 901430.8212354075,
      "turbine_shaft_J": 221123.09141541555,
      "generator_DC_J": 199010.782273874,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 142637.1606139555,
      "gas_exit_temperature_K": 212.2383445814292,
      "boiler_required_UA_W_K": 86.51450833402141,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 381.38424372893434,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1973940.2490545725,
      "retained_exit_N2_availability_J": 28696.627099084668,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1802606.4613415324,
      "net_DC_over_resource_availability_used": 0.07226012068109569,
      "turbine_entropy_generation_J_K": 502.36620419582323,
      "total_entropy_generation_J_K": 6149.092482829734,
      "exergy_entropy_identity_residual_J": -3.958120942115784e-09,
      "complete_steady_first_law_residual_J": 3.2887328416109085e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 675.4473876245056,
      "heat_into_nitrogen_J": 901430.8212354075,
      "turbine_shaft_J": 221123.09141541555,
      "generator_DC_J": 199010.782273874,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 92065.41640366486,
      "gas_exit_temperature_K": 212.2383445814292,
      "boiler_required_UA_W_K": 86.28178154805681,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 382.76347311648766,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1948199.591200131,
      "retained_exit_N2_availability_J": 28696.627099084668,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1827437.5476973816,
      "net_DC_over_resource_availability_used": 0.047256665497476404,
      "turbine_entropy_generation_J_K": 502.36620419582323,
      "total_entropy_generation_J_K": 6233.7968538201685,
      "exergy_entropy_identity_residual_J": -6.984919309616089e-10,
      "complete_steady_first_law_residual_J": 1.2951204553246498e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 678.1909729445555,
      "heat_into_nitrogen_J": 901430.8212354075,
      "turbine_shaft_J": 221123.09141541555,
      "generator_DC_J": 199010.782273874,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": -8532.711998163199,
      "gas_exit_temperature_K": 212.2383445814292,
      "boiler_required_UA_W_K": 85.82261581634867,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 385.50705843653753,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1896876.0974463196,
      "retained_exit_N2_availability_J": 28696.627099084668,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1876712.1823453982,
      "net_DC_over_resource_availability_used": -0.004498296968183853,
      "turbine_entropy_generation_J_K": 502.36620419582323,
      "total_entropy_generation_J_K": 6401.883617074537,
      "exergy_entropy_identity_residual_J": -2.0954757928848267e-09,
      "complete_steady_first_law_residual_J": 1.949956640601158e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 669.0660326689328,
      "heat_into_nitrogen_J": 1029970.2364065076,
      "turbine_shaft_J": 254315.71479361164,
      "generator_DC_J": 228884.14331425048,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 213100.22006937617,
      "gas_exit_temperature_K": 257.9835277955783,
      "boiler_required_UA_W_K": 87.36941351703068,
      "reheater_required_UA_W_K": 15.736784959910116,
      "minimum_boiler_pinch_K": 376.3821181609149,
      "minimum_reheat_pinch_K": 380.2772519539782,
      "resource_availability_used_J": 2066954.2472708598,
      "retained_exit_N2_availability_J": 4779.894088469911,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1849074.1331130136,
      "net_DC_over_resource_availability_used": 0.1030986633355561,
      "turbine_entropy_generation_J_K": 444.8850787362953,
      "total_entropy_generation_J_K": 6307.604069974473,
      "exergy_entropy_identity_residual_J": -3.026798367500305e-09,
      "complete_steady_first_law_residual_J": 1.6298145055770874e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 669.3430826734829,
      "heat_into_nitrogen_J": 1029970.2364065076,
      "turbine_shaft_J": 254315.71479361164,
      "generator_DC_J": 228884.14331425048,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 202941.71990254213,
      "gas_exit_temperature_K": 257.9835277955783,
      "boiler_required_UA_W_K": 87.32161226793899,
      "reheater_required_UA_W_K": 15.726099137845095,
      "minimum_boiler_pinch_K": 376.6591681654649,
      "minimum_reheat_pinch_K": 380.5543019585282,
      "resource_availability_used_J": 2061816.6026142836,
      "retained_exit_N2_availability_J": 4779.894088469911,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1854094.9886232715,
      "net_DC_over_resource_availability_used": 0.09842859915145792,
      "turbine_entropy_generation_J_K": 444.8850787362953,
      "total_entropy_generation_J_K": 6324.731327386227,
      "exergy_entropy_identity_residual_J": -9.313225746154785e-10,
      "complete_steady_first_law_residual_J": 1.1641532182693481e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 670.1730244438886,
      "heat_into_nitrogen_J": 1029970.2364065076,
      "turbine_shaft_J": 254315.71479361164,
      "generator_DC_J": 228884.14331425048,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 172510.52165433197,
      "gas_exit_temperature_K": 257.9835277955783,
      "boiler_required_UA_W_K": 87.17873610180536,
      "reheater_required_UA_W_K": 15.694175091256843,
      "minimum_boiler_pinch_K": 377.48910993587066,
      "minimum_reheat_pinch_K": 381.38424372893394,
      "resource_availability_used_J": 2046416.160882284,
      "retained_exit_N2_availability_J": 4779.894088469911,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1869125.745139482,
      "net_DC_over_resource_availability_used": 0.08429884641839246,
      "turbine_entropy_generation_J_K": 444.8850787362953,
      "total_entropy_generation_J_K": 6376.004588570639,
      "exergy_entropy_identity_residual_J": -6.984919309616089e-10,
      "complete_steady_first_law_residual_J": 1.8335413187742233e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 671.5522538314419,
      "heat_into_nitrogen_J": 1029970.2364065076,
      "turbine_shaft_J": 254315.71479361164,
      "generator_DC_J": 228884.14331425048,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 121938.77744404133,
      "gas_exit_temperature_K": 257.9835277955783,
      "boiler_required_UA_W_K": 86.9423518835368,
      "reheater_required_UA_W_K": 15.641408649721372,
      "minimum_boiler_pinch_K": 378.868339323424,
      "minimum_reheat_pinch_K": 382.76347311648726,
      "resource_availability_used_J": 2020790.3135452345,
      "retained_exit_N2_availability_J": 4779.894088469911,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1894071.6420127233,
      "net_DC_over_resource_availability_used": 0.06034212289453939,
      "turbine_entropy_generation_J_K": 444.8850787362953,
      "total_entropy_generation_J_K": 6461.100603829862,
      "exergy_entropy_identity_residual_J": -6.984919309616089e-10,
      "complete_steady_first_law_residual_J": -5.820766091346741e-11,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 320.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 674.2958391514918,
      "heat_into_nitrogen_J": 1029970.2364065076,
      "turbine_shaft_J": 254315.71479361164,
      "generator_DC_J": 228884.14331425048,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 21340.649042213277,
      "gas_exit_temperature_K": 257.9835277955783,
      "boiler_required_UA_W_K": 86.47600191035113,
      "reheater_required_UA_W_K": 15.537494390281264,
      "minimum_boiler_pinch_K": 381.61192464347386,
      "minimum_reheat_pinch_K": 385.50705843653714,
      "resource_availability_used_J": 1969693.8103416562,
      "retained_exit_N2_availability_J": 4779.894088469911,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1943573.267210973,
      "net_DC_over_resource_availability_used": 0.010834500738219614,
      "turbine_entropy_generation_J_K": 444.8850787362953,
      "total_entropy_generation_J_K": 6629.961682452582,
      "exergy_entropy_identity_residual_J": -1.3969838619232178e-09,
      "complete_steady_first_law_residual_J": 6.111804395914078e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 671.0465222964241,
      "heat_into_nitrogen_J": 964614.0786992955,
      "turbine_shaft_J": 242279.1932261089,
      "generator_DC_J": 218051.27390349802,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 202267.3506586237,
      "gas_exit_temperature_K": 232.39494144172926,
      "boiler_required_UA_W_K": 95.70435467040204,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 350.2772519539785,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 2030191.4663051572,
      "retained_exit_N2_availability_J": 15267.855802961887,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1812656.2598435716,
      "net_DC_over_resource_availability_used": 0.09962969208354508,
      "turbine_entropy_generation_J_K": 502.79697252947153,
      "total_entropy_generation_J_K": 6183.3745858556085,
      "exergy_entropy_identity_residual_J": 0.0,
      "complete_steady_first_law_residual_J": 4.656612873077393e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 671.3235723009741,
      "heat_into_nitrogen_J": 964614.0786992955,
      "turbine_shaft_J": 242279.1932261089,
      "generator_DC_J": 218051.27390349802,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 192108.85049178966,
      "gas_exit_temperature_K": 232.39494144172926,
      "boiler_required_UA_W_K": 95.65033426404746,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 350.5543019585285,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 2025042.0039358698,
      "retained_exit_N2_availability_J": 15267.855802961887,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1817665.2976411183,
      "net_DC_over_resource_availability_used": 0.09486660035614426,
      "turbine_entropy_generation_J_K": 502.79697252947153,
      "total_entropy_generation_J_K": 6200.461530414867,
      "exergy_entropy_identity_residual_J": 0.0,
      "complete_steady_first_law_residual_J": 2.9103830456733704e-11,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 672.1535140713798,
      "heat_into_nitrogen_J": 964614.0786992955,
      "turbine_shaft_J": 242279.1932261089,
      "generator_DC_J": 218051.27390349802,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 161677.6522435795,
      "gas_exit_temperature_K": 232.39494144172926,
      "boiler_required_UA_W_K": 95.48888384313989,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 351.3842437289343,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 2009606.2189942012,
      "retained_exit_N2_availability_J": 15267.855802961887,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1832660.7109476598,
      "net_DC_over_resource_availability_used": 0.08045240441408388,
      "turbine_entropy_generation_J_K": 502.79697252947153,
      "total_entropy_generation_J_K": 6251.614228032269,
      "exergy_entropy_identity_residual_J": 2.3283064365386963e-10,
      "complete_steady_first_law_residual_J": 6.984919309616089e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 673.5327434589332,
      "heat_into_nitrogen_J": 964614.0786992955,
      "turbine_shaft_J": 242279.1932261089,
      "generator_DC_J": 218051.27390349802,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 111105.90803328887,
      "gas_exit_temperature_K": 232.39494144172926,
      "boiler_required_UA_W_K": 95.22181698234787,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 352.7634731164876,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1983921.8298745845,
      "retained_exit_N2_availability_J": 15267.855802961887,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1857548.0660383338,
      "net_DC_over_resource_availability_used": 0.05600316824998722,
      "turbine_entropy_generation_J_K": 502.79697252947153,
      "total_entropy_generation_J_K": 6336.510544220819,
      "exergy_entropy_identity_residual_J": 9.313225746154785e-10,
      "complete_steady_first_law_residual_J": -1.1932570487260818e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 1,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": null,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 676.276328778983,
      "heat_into_nitrogen_J": 964614.0786992955,
      "turbine_shaft_J": 242279.1932261089,
      "generator_DC_J": 218051.27390349802,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 10507.779631460813,
      "gas_exit_temperature_K": 232.39494144172926,
      "boiler_required_UA_W_K": 94.69510934584268,
      "reheater_required_UA_W_K": 0.0,
      "minimum_boiler_pinch_K": 355.5070584365375,
      "minimum_reheat_pinch_K": null,
      "resource_availability_used_J": 1932709.585389766,
      "retained_exit_N2_availability_J": 15267.855802961887,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1906933.9499553433,
      "net_DC_over_resource_availability_used": 0.005436812499350092,
      "turbine_entropy_generation_J_K": 502.79697252947153,
      "total_entropy_generation_J_K": 6504.97680353178,
      "exergy_entropy_identity_residual_J": 2.0954757928848267e-09,
      "complete_steady_first_law_residual_J": -5.384208634495735e-10,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 100.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 666.8016913049322,
      "heat_into_nitrogen_J": 1104693.5014185298,
      "turbine_shaft_J": 278480.1760853878,
      "generator_DC_J": 250632.15847684906,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 10165.904979210985,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 234848.23523197474,
      "gas_exit_temperature_K": 282.256585120386,
      "boiler_required_UA_W_K": 96.53996087124075,
      "reheater_required_UA_W_K": 18.392051383519597,
      "minimum_boiler_pinch_K": 346.0324209624865,
      "minimum_reheat_pinch_K": 350.2772519539801,
      "resource_availability_used_J": 2108882.130338953,
      "retained_exit_N2_availability_J": 432.27782826684415,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1873601.6172787114,
      "net_DC_over_resource_availability_used": 0.11136148002459884,
      "turbine_entropy_generation_J_K": 445.21359627468337,
      "total_entropy_generation_J_K": 6391.272786214275,
      "exergy_entropy_identity_residual_J": -3.026798367500305e-09,
      "complete_steady_first_law_residual_J": 2.6775524020195007e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 200.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 667.0787413094822,
      "heat_into_nitrogen_J": 1104693.5014185298,
      "turbine_shaft_J": 278480.1760853878,
      "generator_DC_J": 250632.15847684906,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 20324.40514604503,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 224689.7350651407,
      "gas_exit_temperature_K": 282.256585120386,
      "boiler_required_UA_W_K": 96.48496444062353,
      "reheater_required_UA_W_K": 18.378650271682023,
      "minimum_boiler_pinch_K": 346.30947096703653,
      "minimum_reheat_pinch_K": 350.5543019585301,
      "resource_availability_used_J": 2103758.0831527933,
      "retained_exit_N2_availability_J": 432.27782826684415,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1878636.0702593857,
      "net_DC_over_resource_availability_used": 0.1068039794425459,
      "turbine_entropy_generation_J_K": 445.21359627468337,
      "total_entropy_generation_J_K": 6408.446427628823,
      "exergy_entropy_identity_residual_J": -3.4924596548080444e-09,
      "complete_steady_first_law_residual_J": 2.1245796233415604e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 500.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 667.908683079888,
      "heat_into_nitrogen_J": 1104693.5014185298,
      "turbine_shaft_J": 278480.1760853878,
      "generator_DC_J": 250632.15847684906,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 50755.60339425518,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 194258.53681693054,
      "gas_exit_temperature_K": 282.256585120386,
      "boiler_required_UA_W_K": 96.32060073738374,
      "reheater_required_UA_W_K": 18.338622264353475,
      "minimum_boiler_pinch_K": 347.1394127374423,
      "minimum_reheat_pinch_K": 351.38424372893587,
      "resource_availability_used_J": 2088398.3071350958,
      "retained_exit_N2_availability_J": 432.27782826684415,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1893707.4924898983,
      "net_DC_over_resource_availability_used": 0.09301795359306629,
      "turbine_entropy_generation_J_K": 445.21359627468337,
      "total_entropy_generation_J_K": 6459.858408630062,
      "exergy_entropy_identity_residual_J": -3.958120942115784e-09,
      "complete_steady_first_law_residual_J": 2.9103830456733704e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 1000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 669.2879124674413,
      "heat_into_nitrogen_J": 1104693.5014185298,
      "turbine_shaft_J": 278480.1760853878,
      "generator_DC_J": 250632.15847684906,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 101327.34760454582,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 143686.7926066399,
      "gas_exit_temperature_K": 282.256585120386,
      "boiler_required_UA_W_K": 96.04872714813922,
      "reheater_required_UA_W_K": 18.272487281892122,
      "minimum_boiler_pinch_K": 348.5186421249956,
      "minimum_reheat_pinch_K": 352.7634731164892,
      "resource_availability_used_J": 2062839.8169674613,
      "retained_exit_N2_availability_J": 432.27782826684415,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1918720.7465325545,
      "net_DC_over_resource_availability_used": 0.06965484737339951,
      "turbine_entropy_generation_J_K": 445.21359627468337,
      "total_entropy_generation_J_K": 6545.184194209642,
      "exergy_entropy_identity_residual_J": -1.862645149230957e-09,
      "complete_steady_first_law_residual_J": 1.0477378964424133e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    },
    {
      "physical_measurements": 0,
      "stages": 2,
      "inlet_temperature_K": 350.0,
      "interstage_expander_outlet_Pa": 330000.0,
      "hot_gas_total_pressure_loss_Pa_target": 2000.0,
      "steady_nitrogen_kg": 2.0,
      "prepared_nitrogen_inventory_kg": 6.0,
      "remaining_N2_before_unknown_startup_kg": 4.0,
      "hot_gas_kg": 30.0,
      "hot_gas_inlet_K": 700.0,
      "hot_gas_outlet_K": 672.0314977874912,
      "heat_into_nitrogen_J": 1104693.5014185298,
      "turbine_shaft_J": 278480.1760853878,
      "generator_DC_J": 250632.15847684906,
      "liquid_pump_DC_J": 3618.018265663327,
      "hot_gas_blower_DC_J": 201925.47600637388,
      "control_DC_J": 2000.0,
      "net_steady_DC_J": 43088.66420481185,
      "gas_exit_temperature_K": 282.256585120386,
      "boiler_required_UA_W_K": 95.51258474099778,
      "reheater_required_UA_W_K": 18.142341703447208,
      "minimum_boiler_pinch_K": 351.2622274450455,
      "minimum_reheat_pinch_K": 355.50705843653907,
      "resource_availability_used_J": 2011876.481114176,
      "retained_exit_N2_availability_J": 432.27782826684415,
      "exergy_destroyed_with_ambient_loss_rejection_J": 1968355.5390810973,
      "net_DC_over_resource_availability_used": 0.021417151902362003,
      "turbine_entropy_generation_J_K": 445.21359627468337,
      "total_entropy_generation_J_K": 6714.499536350327,
      "exergy_entropy_identity_residual_J": -6.984919309616089e-10,
      "complete_steady_first_law_residual_J": 1.57160684466362e-09,
      "full_6kg_liquid_preparation_reversible_floor_J": 4450117.254184179,
      "startup_and_hardware_credit": "None. Startup, metal transients, materials and installed hardware mass are not closed; no vehicle energy credit."
    }
  ],
  "assumptions": {
    "nitrogen_real_fluid": "CoolProp Nitrogen",
    "turbine_isentropic_efficiency": 0.7,
    "generator_efficiency": 0.9,
    "pump_hydraulic_efficiency": 0.7,
    "motor_efficiency": 0.9,
    "hot_gas_model": "Ideal generic dry heat-source gas, Cp=1100 J/kgK, R=287.05 J/kgK; no combustion chemistry credited.",
    "hot_gas_total_mass_kg": 30.0,
    "duty_s": 20.0,
    "heat_source_note": "Finite external hot stream. Engine waste heat is a future integration option, requiring measured heat, pressure loss and fuel accounting."
  },
  "limits": [
    "Steady-flow control volume only. Do not compare these net values directly with the P3.6 startup-inclusive 76 kJ account.",
    "The hot gas is an explicit prepared resource; it is not ambient free heat or a new energy source.",
    "Both layouts share the same total pressure-loss target; the extra core would have to meet that target in actual hardware.",
    "Cold preparation, unspent liquid and cold outlet availability remain distinct.",
    "Heat-transfer area, pressure duty, phase distribution, material gradients, startup inventory and total installed mass remain unqualified.",
    "Driving-model energy credit is zero."
  ]
}